ACO Clara C

Wastewater Treatment Plant

Treatment processes

  • Mechanical pre-treatment
  • Biological treatment by activated sludge
  • Sludge separation in final sedimentation tank

Treatment efficiency

A long-term trial run in accordance with the European standard EN 12566-3, performed in an accredited laboratory, has shown the following discharge values:

BOD₅………………………………..6.7 mg/l

COD……………………………….59.6 mg/l

TSS…………………………………..6.1 mg/l

N-NH₄……………………………….2.0 mg/l

Features

  • Maximum flexibility
  • Low operating costs
  • Easy installation
  • Easy operation
  • Arranged service
  • Odour-proof cover

2Aa_obr. 006_CE_pouze print screen

ACO Clara wastewater treatment plants comply with the European standard EN 12566-3, which is proven by a CE certificate.

10 years guarantee!

We guarantee the quality of our work. We are the only company on the market to offer a 10 – year guarantee for static properties and water resistance of all our tanks. We trust the materials we use, and we are not ashamed to sign our name to our work.

2Aa_obr. 007_10 let garance_pouze print screen

Technical Information

Technical Information
ACO Clara C 3 – 6 5 – 10 15 – 29 30 – 60
Nominal size in PE 5 8 24 50
Hydraulic load [mᶟ/day] 0.45 – 0.90 0.75 – 1.50 2.25 – 4.35 4.5 – 9.0
Biological load BSK₅ [kg/day] 0.18 – 0.36 0.30 – 0.60 0.90 – 1.74 1.80 – 3.60
Diameter D [mm] 1470 1800 2440 2440
Height H [mm] 1960 2080 2830 2830
Number of tanks 1 1 1 2
Technical Information
ACO Clara C 48 – 96 60 – 120 96 – 192 120 – 240
Nominal size in PE 80 100 160 200
Hydraulic load [mᶟ/day] 7.2 – 14.4 9.0 – 18.0 14.4 – 28.8 18.0 – 36.0
Biological load BSK₅ [kg/day] 2.88 – 5.76 3.60 – 7.20 5.76 – 11.52 7.20 – 14.4
Diameter D [mm] 2440 2440 2440 2440
Height H [mm] 2830 2830 2830 2830
Number of tanks 3 4 6 7